(helpful information only, detailed reference should be taken from an appropriate agency)

An IP number contains two numbers (i.e. IP65) in most instances which relate to the
level of protection provided by an enclosure or housing.

The first number relates to protection from solids as follows:

0: No Special Protection
1: Protected against solid objects up to 50 mm in diameter
2: Protected against solid objects up to 12 mm in diameter
3: Protected against solid objects up to 2.5 mm in diameter
4: Protected against solid objects up to 1 mm in diameter
5: Dust protected
6: Dust tight

The second number relates to protection from liquids as follows:

0: No special protection
1: Protected against dripping water
2: Protected against dripping water when tilted up to 15o from normal position
3: Protected against spraying water
4: Protected against splashing water
5: Protected against water jet spray
6: Protected against heavy jet spray
7: Protected against the effects of immersion
8: Protected against submersion

Example: IP66 = Dust tight and protected against heavy water jet spray

BACK TO TOP

NEMA (National Electrical Manufacturers Association) ratings can be approximately compared to those of the IP system as shown below.
Other factors such as corrosion protection are also involved in the NEMA system, please refer to official documentation for details.

NEMA 1 = IP10
NEMA 2 = IP11
NEMA 3 = IP54
NEMA 4 = IP56
NEMA 4X = IP66
NEMA 6 = IP67
NEMA 12 = IP52
NEMA 13 = IP54

BACK TO TOP

ATEX & Intrinsic Safety Information - Explosive Atmospheres
(helpful information only, detailed reference should be taken from an appropriate agency)

Protection Concepts

ZONE

HAZARD

PROTECTION CONCEPTS

0

In which an explosive gas/air mixture is continuously present for long periods

Exia or Exs

1

In which an explosive gas/air mixture is likely to occur in normal operation.

Exd. Exe, Exib, Exp, Exia, Exs

2

In which an explosive gas/air mixture is not likely to occur in normal operation.

All concepts suitable for
Zone 0 & 1, ExN, ExO and Exq

BACK TO TOP

Standards For Methods Of Protection

METHOD OF PROTECTION

PERMITTED ZONE
OF USE IN UK

CODE LETTER
IEC, EX.., CENELEC, EEX

General requirement

-

-

Oil immersion

2

o

Pressurisation

1 or 2

p

Powder filling

2

q

Flameproof

1 or 2

d

Increased safety

1 or 2

e

Intrinsic safety

* 0, 1 or 2

ia or ib

Non-incendive

2

n #

Encapsulation

1 or 2

m

Special

1 or 2

s

* ia: Zone 0,1,2. ib: Zone 1,2. not Zone 0. # n: used locally in UK.


BACK TO TOP

Gas Grouping

 

Temperature Classification

GAS # GROUP
CENELEC
EN 50 014, IEC

REPRESENTATIVE GAS

 

T Class / IEC 79-7

Max. surface temp ° C

I * (mining)

Methane

 

T1

450 ° C

IIA

Propane

 

T2

300 ° C

IIB

Ethylene

 

T3

200 ° C

IIC

Hydrogen

 

T4

135 ° C

 

 

 

T5

100 ° C

 

 

 

T6

85 ° C


Certification Code
(CENELEC marking information - example [EEx ia] IIC T4)

[

E

Ex

ia

]

IIC

T4

Associated apparatus*

Certified to the CENELEC standard

Explosion protected

Protection
concept (IS)

Associated
apparatus*

Apparatus
group
(gas group)

Temperature
classification
(not Gp I)

* (located in safe area and may be connected to hazardous area)


BACK TO TOP

Device Group & Category    

DEVICE GROUP

DEVICE CATEGORY

ZONE

I

M = mining

Mining

M 1

Pit gas &/or flammable dusts

M 2

II

G = gas

 

Other areas

1 G

0, 1, 2

Explosive atmosphere

2 G

1, 2

 

3 G

2

D is added after G in the certification class number

D = dust

 

(i.e. GD) if device is dust category approved also

1 D

20, 21, 22

 

2 D

21, 22

BACK TO TOP

3 D

22

Explanation of the categories:

1 - Very high safety = device safety must be guaranteed even in case of rare device failures, e.g. simultaneous failure of two components.

2 - High safety = device safety must be guaranteed if frequent failures can be expected, e.g. failure of one component.

3 – Safe in normal operation = device safety must be guaranteed in normal operation.

Note: A number in brackets before device category designation signifies that the device meets the requirements of an additional category to the main one that is specified.

Example: II (1) 2G signifies that the device meets requirements for both
1 G and 2 G categories

BACK TO TOP

Characteristics of Substances

Flashpoint

This is the lowest temperature at which a liquid generates sufficient
vapour to support ignition. This vapour can be ignited in many ways
including temperature or energy (i.e. a spark)

Ignition Temperature

This is the lowest temperature at which the vapour will be ignited.
This defines the temperature class.

Classification of maximum surface temperatures of electrical apparatus (CENELEC)

Temp. Class

Max. Surface Temp.

T1

<450ºC

T2

<300ºC

T3

<200ºC

T4

<135ºC

T5

<100ºC

T6

<85ºC

BACK TO TOP

Apparatus Group (energy ignition)
All surface industry gases/vapours are classed as Group II gases.
Group II is divided into 3 sub groups:

IIA – High energy is required to ignite. Less intense explosion. (Propane)

IIB – Less energy is required to ignite. More intense explosion. (Ethylene)

IIC – Little energy is required to ignite. Most intense explosion. (Hydrogen)

Characteristics of some common flammable materials

Gas/Vapour

Flashpoint

Gas Group

Ignition Temp.

Temp. Class

Acetone

19ºC

IIA

535ºC

T1

Butane

-60ºC

IIA

365ºC

T2

Heptane

-4C

IIA

215ºC

T3

Ethyl Methyl Ether

37ºC

IIB

190ºC

T4

Note: There is no connection between ignition energy and ignition temperature

BACK TO TOP

Conversion Program

'Convert!' is a small program that allows you to convert one set of engineering units to another quickly, easily and exactly with up to 10 decimal place precision possible!

Click on the arrows below to download your copy

Click Here To Download Convert!

Convert consists of a single file named convert.exe that is only 548KB in size.  When you click on the image opposite to download, simply choose 'save' when prompted and select a directory to put the file into. Once download is complete, locate the file and double-click the icon and the program will open.

To put a shortcut on the
desktop for easy access, right-click the icon,then left-click 'Send To' followed by 'Desktop (create shortcut)'...and that's it!

 
Click Here To Send Us An E-Mail